With the improvement of people's living standard, consumers begin to have higher demands to the quality of clothing, food, housing and transportation, especially of food, beverage, medicine and automobile products. Since quality of these products is closely related with people's life, it becomes the focus of attention of numerous enterprises and manufacturers. Among them, quality control of material is an important aspect of product quality. To help material suppliers have a better understanding of their product quality,Labthink Lab will offer service of commission for specimen testing to the society publicly.
1.Testing Scope:
1.1 Film permeability testing:
1.1.1 Oxygen permeability testing of various films
1.1.2 Nitrogen permeability testing of various films
1.1.3 Carbon dioxide permeability testing of various films
1.1.4 Water vapor permeability testing of various films
Common testing materials: PE,LDPE,HDPE ,PP ,BOPP,CPP,PET,PA,EVOH,EVAL,PVC, PVDC, AL, KOP, KPET, KPA, KMF,aluminum plated PET, aluminum coated CPP, BOPP with matte surface treatment, PA/AL/CPP , PA/PU ,PET/AL/PA , PE/AL/PET,five-layer co-extrusion film, seven- layer co-extrusion film
1.2 Oxygen permeability testing of various bottle package and bag package:
Common testing products: beer bottle, coke bottle and mineral water bottle.
1.3 Automotive interior decoration testing:
1.3.1 Atomizing testing
Scope of material: foamed materials, textile, non-woven fabrics, leatheroid, leather, instrument board, headlight, and cushion material, cotton cloth; Test the atomizing property of raw material in the state of liquid, paste, powder and solid.
1.3.2 Auto gas permeability testing
Leather, leatheroid, non-woven fabrics, thermal insulating film, battery diaphragm of various kinds
1.3.3 Water vapor permeability testing
Leather, leatheroid, non-woven fabrics, fabrics
1.3.4 Adhesive strength testing
Various adhesive products
2.Operation Flow

3. Rates of charges
Schedule of fees for testing items (F.1)
|
Testing Categories |
Name |
Testing Method |
Testing Standard |
Price (USD/sample) | |
|
Normal ( 14working days ) |
Urgent ( 7working days ) | ||||
|
Gas Permeability ( film ) |
Oxygen Permeability Testing |
Equal Pressure Method |
ASTM D3985 |
180 |
200 |
|
Differential Pressure Method |
GB 1038 |
80 |
100 | ||
|
Nitrogen Permeability Testing |
Differential Pressure Method |
GB 1038 |
100 |
120 | |
|
Carbon Dioxide Permeability Testing |
Differential Pressure Method |
GB 1038 |
100 |
120 | |
|
Air Permeability Testing |
Differential Pressure Method |
GB 1038 |
80 |
100 | |
|
Other |
Customer require |
To be negotiated | |||
|
Water Vapor Permeability Testing (Film) |
Water |
Cup Method |
GB 1037 |
80 |
100 |
|
Sensor Method |
ASTM E398 |
100 |
120 | ||
|
Electrolyzing Method |
ISO 15106-3 |
100 |
120 | ||
|
Finished Package |
Oxygen Permeability Testing |
Equal Pressure Method |
ASTM F1307 |
180 |
200 |
|
Fogging Testing |
Fogging |
Standard |
DIN 75201 |
100 |
130 |
|
Other |
Common index testing such as tension, strength tearing, impact, friction coefficient and heat sealing property |
Customer require |
To be negotiated | ||
Note: about "normal"
- Testing period of specimen longer than two weeks is an exception
- Testing cannot be carried out for unexpected factors is an exception
4.Things to be Noted
4.1 Labthink Lab is only responsible for testing data and will not involved in solving legal disputes.
4.2 Requirement of specimen:
Appearance of specimen: No crease, no scratches, no pinholes and no contamination; package specimen without crumple, without contamination, without sloughing of permeable layer and no extrusion from outside force.
Specimen dimension
auto gas permeability testing:( O2, N2, CO2, etc )
specimen dimension of differential pressure method ≥ 120mm X 120mm ( VAC-V1 , BTY-B1P )
specimen dimension of equal pressure method ≥ 140mm X 140mm ( Oxygen permeability testing )
testing requirement of package : inner diameter of bottle mouth> Φ13mm, external diameter < Φ50mm
water vapor permeability testing :
- sensor method :≥ 110mm X 180mm
- electrolyzing method : ≥ 120mm X 120mm
- cup method : ≥ 120mm X 120mm
- atomizing method : ≥Φ80mm X 6
- specimen member : ≥ three / specimen of each kind/testing of each kind
4.3 Customers should provide information such as the full name, specification, material ,batch number of specimen and information about whether specimen should be returned.
4.4 Make clear the testing basis, testing standard and orientation of gas transmission.